{"product_id":"kleenoil-ldu9768ku16-light-duty-oil-filtration-system","title":"KLEENOIL LDU9768KU16 LIGHT DUTY OIL FILTRATION SYSTEM","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"3691\" data-end=\"3749\"\u003eCompact size. Powerful protection. Proven performance.\u003c\/strong\u003e\u003cbr data-start=\"3749\" data-end=\"3752\"\u003eLight-duty bypass filtration for smaller systems and tight installations.\u003cbr data-start=\"3825\" data-end=\"3828\"\u003eSimple to install, delivering continuous oil cleanliness,\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pwqm1a\" data-start=\"185\" data-end=\"218\"\u003e🔹 Detail\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for engines of up to 16 litres oil\u003c\/li\u003e\n\u003cli\u003eMax input pressure 2-6 Bar\u003c\/li\u003e\n\u003cli\u003eLid torque pressure 18ft lbs. Single bolt seal\u003c\/li\u003e\n\u003cli\u003eHeight: 160mm\u003c\/li\u003e\n\u003cli\u003eDiameter: 120mm\u003c\/li\u003e\n\u003cli\u003eWeight: 2.25k\u003c\/li\u003e\n\u003cli\u003eWater Retention: 200ml\u003c\/li\u003e\n\u003cli\u003eSupplied with 1x LDFC1868kf16 Replacement Filter Cartridge\u003c\/li\u003e\n\u003cli\u003eComplete with bracket mounting kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pwqm1a\" data-start=\"185\" data-end=\"218\"\u003e🔹 Why You Need This System\u003c\/h3\u003e\n\u003cp data-start=\"220\" data-end=\"460\"\u003eEven in smaller engines and systems, oil contamination is one of the biggest causes of wear, inefficiency, and premature failure. Fine particles and moisture quickly degrade oil quality, reducing protection and increasing maintenance costs.\u003c\/p\u003e\n\u003cp data-start=\"462\" data-end=\"781\"\u003eThe KLEENOIL LDU9768KU16 Light Duty By-Pass Filtration Unit provides continuous oil conditioning while your system is running—removing contamination and water to maintain oil in near “as new” condition. This results in longer oil life, improved performance, and reduced downtime.\u003c\/p\u003e\n\u003chr data-start=\"783\" data-end=\"786\"\u003e\n\u003ch3 data-section-id=\"1ar34yn\" data-start=\"788\" data-end=\"812\"\u003e🔹 Suitability\u003c\/h3\u003e\n\u003cp data-start=\"814\" data-end=\"873\"\u003eDesigned for smaller systems, the LDU9768KU16 is ideal for:\u003c\/p\u003e\n\u003cul data-start=\"875\" data-end=\"1055\"\u003e\n\u003cli data-section-id=\"c8dxla\" data-start=\"875\" data-end=\"925\"\u003eEngines (up to approx. 16 litre sump capacity)\u003c\/li\u003e\n\u003cli data-section-id=\"1o0gvhw\" data-start=\"926\" data-end=\"953\"\u003eSmall hydraulic systems\u003c\/li\u003e\n\u003cli data-section-id=\"1es8j3o\" data-start=\"954\" data-end=\"985\"\u003eGearboxes and transmissions\u003c\/li\u003e\n\u003cli data-section-id=\"oa3uix\" data-start=\"986\" data-end=\"1024\"\u003eMobile plant and compact equipment\u003c\/li\u003e\n\u003cli data-section-id=\"7b9d3f\" data-start=\"1025\" data-end=\"1055\"\u003eGenerators and compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1057\" data-end=\"1205\"\u003eIt is particularly suited to applications where space is limited but maintaining clean oil remains critical.\u003c\/p\u003e\n\u003chr data-start=\"1207\" data-end=\"1210\"\u003e\n\u003ch3 data-section-id=\"f87jlp\" data-start=\"1212\" data-end=\"1233\"\u003e🔹 How It Works\u003c\/h3\u003e\n\u003cp data-start=\"1235\" data-end=\"1359\"\u003eThe unit operates as a \u003cstrong data-start=\"1258\" data-end=\"1286\"\u003ebypass filtration system\u003c\/strong\u003e, continuously cleaning oil without interrupting normal system operation.\u003c\/p\u003e\n\u003cul data-start=\"1361\" data-end=\"1560\"\u003e\n\u003cli data-section-id=\"118kd6g\" data-start=\"1361\" data-end=\"1411\"\u003eA small volume of oil is taken from the system\u003c\/li\u003e\n\u003cli data-section-id=\"12rkm0i\" data-start=\"1412\" data-end=\"1479\"\u003eOil is passed slowly through a high-efficiency cellulose filter\u003c\/li\u003e\n\u003cli data-section-id=\"146736t\" data-start=\"1480\" data-end=\"1515\"\u003eParticles and water are removed\u003c\/li\u003e\n\u003cli data-section-id=\"1g4iavu\" data-start=\"1516\" data-end=\"1560\"\u003eClean oil is returned back to the system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1562\" data-end=\"1787\"\u003eThis controlled filtration process achieves \u003cstrong data-start=\"1606\" data-end=\"1638\"\u003e3 micron absolute filtration\u003c\/strong\u003e and removes up to \u003cstrong data-start=\"1657\" data-end=\"1675\"\u003e99.9% of water\u003c\/strong\u003e, significantly improving oil condition and extending service intervals.\u003c\/p\u003e\n\u003chr data-start=\"1789\" data-end=\"1792\"\u003e\n\u003ch3 data-section-id=\"1a3ebv5\" data-start=\"1794\" data-end=\"1815\"\u003e🔹 Key Benefits\u003c\/h3\u003e\n\u003cul data-start=\"1817\" data-end=\"2105\"\u003e\n\u003cli data-section-id=\"ku361v\" data-start=\"1817\" data-end=\"1868\"\u003eRemoves particles down to \u003cstrong data-start=\"1845\" data-end=\"1866\"\u003e3 micron absolute\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1soqvoz\" data-start=\"1869\" data-end=\"1926\"\u003eRemoves \u003cstrong data-start=\"1879\" data-end=\"1894\"\u003e99.9% water\u003c\/strong\u003e (free, emulsified, dissolved)\u003c\/li\u003e\n\u003cli data-section-id=\"a0y709\" data-start=\"1927\" data-end=\"1963\"\u003eExtends oil life by up to \u003cstrong data-start=\"1955\" data-end=\"1961\"\u003e5x\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gbijhv\" data-start=\"1964\" data-end=\"2013\"\u003eReduces wear, downtime, and maintenance costs\u003c\/li\u003e\n\u003cli data-section-id=\"w9hxd4\" data-start=\"2014\" data-end=\"2060\"\u003eImproves system efficiency and reliability\u003c\/li\u003e\n\u003cli data-section-id=\"16csk5d\" data-start=\"2061\" data-end=\"2105\"\u003eCompact design for smaller installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2107\" data-end=\"2110\"\u003e\n\u003ch3 data-section-id=\"k51pgo\" data-start=\"2112\" data-end=\"2158\"\u003e🔹 Installation (Simple \u0026amp; Non-Intrusive)\u003c\/h3\u003e\n\u003cp data-start=\"2160\" data-end=\"2253\"\u003eThe LDU9768KU16 is designed for quick and straightforward installation into existing systems.\u003c\/p\u003e\n\u003cp data-start=\"2255\" data-end=\"2285\"\u003eThe system is installed using:\u003c\/p\u003e\n\u003cul data-start=\"2286\" data-end=\"2407\"\u003e\n\u003cli data-section-id=\"6tcuoi\" data-start=\"2286\" data-end=\"2343\"\u003e\n\u003cstrong data-start=\"2288\" data-end=\"2315\"\u003eA pressure feed (inlet)\u003c\/strong\u003e from a low-pressure point\u003c\/li\u003e\n\u003cli data-section-id=\"1o7fxqq\" data-start=\"2344\" data-end=\"2407\"\u003e\n\u003cstrong data-start=\"2346\" data-end=\"2380\"\u003eA low-pressure return (outlet)\u003c\/strong\u003e back to the tank or sump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ve3ig1\" data-start=\"2409\" data-end=\"2427\"\u003eTypical setup:\u003c\/h3\u003e\n\u003cp data-start=\"2429\" data-end=\"2463\"\u003e\u003cstrong data-start=\"2429\" data-end=\"2461\"\u003e1. Feed Line (Pressure Side)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2464\" data-end=\"2523\"\u003e\n\u003cli data-section-id=\"1gcp41m\" data-start=\"2464\" data-end=\"2523\"\u003eTake from an oil gallery or auxiliary low-pressure port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2525\" data-end=\"2560\"\u003e\u003cstrong data-start=\"2525\" data-end=\"2558\"\u003e2. Return Line (Low Pressure)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2561\" data-end=\"2647\"\u003e\n\u003cli data-section-id=\"1wicwuz\" data-start=\"2561\" data-end=\"2602\"\u003eReturn to sump, tank, or filler point\u003c\/li\u003e\n\u003cli data-section-id=\"7himnu\" data-start=\"2603\" data-end=\"2647\"\u003eTypically via dipstick or return fitting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2649\" data-end=\"2666\"\u003e\u003cstrong data-start=\"2649\" data-end=\"2664\"\u003e3. Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2667\" data-end=\"2789\"\u003e\n\u003cli data-section-id=\"uot3x7\" data-start=\"2667\" data-end=\"2716\"\u003eInstall vertically using the supplied bracket\u003c\/li\u003e\n\u003cli data-section-id=\"y4315d\" data-start=\"2717\" data-end=\"2752\"\u003eKeep pipe runs short and direct\u003c\/li\u003e\n\u003cli data-section-id=\"1cx3vkr\" data-start=\"2753\" data-end=\"2789\"\u003eEnsure easy access for servicing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2791\" data-end=\"2962\"\u003e\u003cem data-start=\"2794\" data-end=\"2806\"\u003eImportant:\u003c\/em\u003e Always install on a low-pressure feed. For hydraulic applications, a pressure reducing valve (PRV) may be required.\u003c\/p\u003e\n\u003chr data-start=\"2964\" data-end=\"2967\"\u003e\n\u003ch3 data-section-id=\"1vlnzwy\" data-start=\"2969\" data-end=\"2998\"\u003e🔹 Technical Highlights\u003c\/h3\u003e\n\u003cul data-start=\"3000\" data-end=\"3302\"\u003e\n\u003cli data-section-id=\"l7romy\" data-start=\"3000\" data-end=\"3037\"\u003e\n\u003cstrong data-start=\"3002\" data-end=\"3017\"\u003eFiltration:\u003c\/strong\u003e 3 micron absolute\u003c\/li\u003e\n\u003cli data-section-id=\"csnke6\" data-start=\"3038\" data-end=\"3068\"\u003e\n\u003cstrong data-start=\"3040\" data-end=\"3054\"\u003eFlow Rate:\u003c\/strong\u003e 120–250 L\/h\u003c\/li\u003e\n\u003cli data-section-id=\"1t8w8r8\" data-start=\"3069\" data-end=\"3120\"\u003e\n\u003cstrong data-start=\"3071\" data-end=\"3090\"\u003eWater Capacity:\u003c\/strong\u003e Approx. 200ml per cartridge\u003c\/li\u003e\n\u003cli data-section-id=\"1u3i8a7\" data-start=\"3121\" data-end=\"3167\"\u003e\n\u003cstrong data-start=\"3123\" data-end=\"3149\"\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +120°C\u003c\/li\u003e\n\u003cli data-section-id=\"3ax9mi\" data-start=\"3168\" data-end=\"3211\"\u003e\n\u003cstrong data-start=\"3170\" data-end=\"3187\"\u003eConstruction:\u003c\/strong\u003e Aluminium LM6 housing\u003c\/li\u003e\n\u003cli data-section-id=\"1tdk4hc\" data-start=\"3212\" data-end=\"3261\"\u003e\n\u003cstrong data-start=\"3214\" data-end=\"3230\"\u003eSystem Type:\u003c\/strong\u003e Continuous bypass filtration\u003c\/li\u003e\n\u003cli data-section-id=\"xk6498\" data-start=\"3262\" data-end=\"3302\"\u003e\n\u003cstrong data-start=\"3264\" data-end=\"3287\"\u003eReplacement Filter:\u003c\/strong\u003e LDFC1868KF16\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3304\" data-end=\"3307\"\u003e\n\u003ch3 data-section-id=\"w3i3n1\" data-start=\"3309\" data-end=\"3346\"\u003e🔹 Support \u0026amp; Application Advice\u003c\/h3\u003e\n\u003cp data-start=\"3348\" data-end=\"3570\"\u003eKLEENOIL UK provides a complete support service, working with you to identify the most effective filtration solution for your application. Our goal is simple—deliver consistently clean oil and long-term system performance.\u003c\/p\u003e\n\u003cp data-start=\"3572\" data-end=\"3646\"\u003eSpeak to our team directly on \u003cstrong data-start=\"3602\" data-end=\"3625\"\u003e+44 (0) 1977 682810\u003c\/strong\u003e for tailored advice.\u003c\/p\u003e","brand":"Kleenoil ","offers":[{"title":"Default Title","offer_id":52606135697755,"sku":null,"price":203.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1002\/7499\/5547\/files\/LDU9768KU16_Light_Duty_Filter_Unit_-_Render.jpg?v=1776144839","url":"https:\/\/kleenoil.myshopify.com\/products\/kleenoil-ldu9768ku16-light-duty-oil-filtration-system","provider":"Kleenoil  Hydraulics","version":"1.0","type":"link"}