{"product_id":"kleenoil-original-sdfc2088kf85-polypropylene-for-water-based-fluids-only","title":"KLEENOIL ORIGINAL -  SDFC2088KF85 Polypropylene for water based fluids only SDFC-P","description":"\u003ch2 data-section-id=\"ik07ie\" data-start=\"246\" data-end=\"317\"\u003eSDFC2088KF85 SDFC-P Super Duty Polypropylene Depth Filter Cartridge (Water-Based Fluids)\u003c\/h2\u003e\n\u003cp data-start=\"319\" data-end=\"513\"\u003eThis high-efficiency depth filter cartridge is designed as a direct-fit element for compatible bypass filtration units, offering reliable fine particle removal in water-based fluid applications.\u003c\/p\u003e\n\u003cp data-start=\"515\" data-end=\"588\"\u003e\u003cstrong data-start=\"515\" data-end=\"530\"\u003eDimensions:\u003c\/strong\u003e\u003cbr data-start=\"530\" data-end=\"533\"\u003eHeight: 100mm\u003cbr data-start=\"546\" data-end=\"549\"\u003eDiameter: 200mm\u003cbr data-start=\"564\" data-end=\"567\"\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"595\" data-end=\"614\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"616\" data-end=\"847\"\u003eThis cartridge is manufactured from \u003cstrong data-start=\"652\" data-end=\"703\"\u003etightly wound 5-micron polypropylene needlefelt\u003c\/strong\u003e, formed into a dense, single-structure element with upper and lower support discs to ensure a secure fit and consistent filtration performance.\u003c\/p\u003e\n\u003cp data-start=\"849\" data-end=\"1012\"\u003eUnlike traditional cellulose-based elements, this design is \u003cstrong data-start=\"909\" data-end=\"949\"\u003efully synthetic and chemically inert\u003c\/strong\u003e, making it ideal for use with \u003cstrong data-start=\"980\" data-end=\"1000\"\u003ewater-based oils\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"1014\" data-end=\"1122\"\u003e\n\u003cli data-section-id=\"1oya0y7\" data-start=\"1014\" data-end=\"1045\"\u003eMetalworking cutting fluids\u003c\/li\u003e\n\u003cli data-section-id=\"3vtq15\" data-start=\"1046\" data-end=\"1057\"\u003eGlycols\u003c\/li\u003e\n\u003cli data-section-id=\"1dtzbz7\" data-start=\"1058\" data-end=\"1122\"\u003eWater-mixed coolants (mineral, semi-synthetic and synthetic)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1124\" data-end=\"1289\"\u003eThe construction provides \u003cstrong data-start=\"1150\" data-end=\"1189\"\u003ehigh-efficiency particulate removal\u003c\/strong\u003e, capturing fine contamination such as swarf, carbon, and debris, while maintaining fluid integrity.\u003c\/p\u003e\n\u003chr data-start=\"1291\" data-end=\"1294\"\u003e\n\u003ch2 data-section-id=\"25xzad\" data-start=\"1296\" data-end=\"1321\"\u003eFiltration Performance\u003c\/h2\u003e\n\u003cp data-start=\"1323\" data-end=\"1496\"\u003eThe tightly rolled needlefelt media creates a \u003cstrong data-start=\"1369\" data-end=\"1404\"\u003etrue depth filtration structure\u003c\/strong\u003e, allowing contaminants to be retained throughout the media rather than only on the surface.\u003c\/p\u003e\n\u003cul data-start=\"1498\" data-end=\"1728\"\u003e\n\u003cli data-section-id=\"u2njii\" data-start=\"1544\" data-end=\"1594\"\u003eDesigned for \u003cstrong data-start=\"1559\" data-end=\"1592\"\u003efine particulate removal only\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"iwu4jt\" data-start=\"1595\" data-end=\"1652\"\u003e\n\u003cstrong data-start=\"1597\" data-end=\"1622\"\u003eDoes not remove water\u003c\/strong\u003e (unlike cellulose elements)\u003c\/li\u003e\n\u003cli data-section-id=\"3gkrje\" data-start=\"1653\" data-end=\"1728\"\u003eMaintains stability in water-based environments without media breakdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1730\" data-end=\"1841\"\u003eAs fluid passes through the cartridge, contaminants are trapped within the layered fibre structure, helping to:\u003c\/p\u003e\n\u003cul data-start=\"1843\" data-end=\"1952\"\u003e\n\u003cli data-section-id=\"5lgjb6\" data-start=\"1843\" data-end=\"1874\"\u003eReduce particulate build-up\u003c\/li\u003e\n\u003cli data-section-id=\"nec008\" data-start=\"1875\" data-end=\"1905\"\u003eMaintain fluid cleanliness\u003c\/li\u003e\n\u003cli data-section-id=\"114y1l6\" data-start=\"1906\" data-end=\"1952\"\u003eImprove system performance and consistency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1954\" data-end=\"1957\"\u003e\n\u003ch2 data-section-id=\"17xbmye\" data-start=\"1959\" data-end=\"1974\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1976\" data-end=\"2308\"\u003e\n\u003cli data-section-id=\"bl31r6\" data-start=\"1976\" data-end=\"2033\"\u003ePurpose-built for \u003cstrong data-start=\"1996\" data-end=\"2031\"\u003ewater-based fluids and coolants\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"yxqgj0\" data-start=\"2034\" data-end=\"2085\"\u003e\u003cstrong data-start=\"2036\" data-end=\"2083\"\u003eChemically inert polypropylene construction\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"st4g5x\" data-start=\"2086\" data-end=\"2141\"\u003eHigh dirt-holding capacity through depth filtration\u003c\/li\u003e\n\u003cli data-section-id=\"bl69u2\" data-start=\"2142\" data-end=\"2202\"\u003eHelps extend fluid life and reduce maintenance frequency\u003c\/li\u003e\n\u003cli data-section-id=\"5y4gez\" data-start=\"2203\" data-end=\"2253\"\u003eStable performance without affecting emulsions\u003c\/li\u003e\n\u003cli data-section-id=\"5fk957\" data-start=\"2254\" data-end=\"2308\"\u003eDirect replacement for compatible filtration units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2310\" data-end=\"2313\"\u003e\n\u003ch2 data-section-id=\"4097bv\" data-start=\"2315\" data-end=\"2335\"\u003eApplication Areas\u003c\/h2\u003e\n\u003cul data-start=\"2337\" data-end=\"2485\"\u003e\n\u003cli data-section-id=\"qi385n\" data-start=\"2337\" data-end=\"2375\"\u003eMetalworking and machining centres\u003c\/li\u003e\n\u003cli data-section-id=\"k5n0ia\" data-start=\"2376\" data-end=\"2406\"\u003eCoolant filtration systems\u003c\/li\u003e\n\u003cli data-section-id=\"hucne6\" data-start=\"2407\" data-end=\"2438\"\u003eIndustrial fluid management\u003c\/li\u003e\n\u003cli data-section-id=\"1xsly40\" data-start=\"2439\" data-end=\"2485\"\u003eGlycol and water-based lubrication systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2487\" data-end=\"2490\"\u003e\n\u003ch2 data-section-id=\"k5wsdq\" data-start=\"2492\" data-end=\"2518\"\u003eQuality \u0026amp; Manufacturing\u003c\/h2\u003e\n\u003cp data-start=\"2520\" data-end=\"2717\"\u003eManufactured to strict quality standards, each cartridge is produced using consistent, high-grade polypropylene media to ensure reliable filtration performance in demanding industrial environments.\u003c\/p\u003e\n\u003chr data-start=\"2719\" data-end=\"2722\"\u003e\n\u003ch2 data-section-id=\"1x5xxf7\" data-start=\"2724\" data-end=\"2741\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2743\" data-end=\"2939\"\u003eThis cartridge is designed for \u003cstrong data-start=\"2774\" data-end=\"2805\"\u003eparticulate filtration only\u003c\/strong\u003e and does not offer water removal capability. For oil and water separation applications, a cellulose-based element should be selected.\u003c\/p\u003e\n\u003chr data-start=\"2941\" data-end=\"2944\"\u003e\n\u003ch2 data-section-id=\"1ct8b5\" data-start=\"2946\" data-end=\"2971\"\u003eNeed a Different Size?\u003c\/h2\u003e\n\u003cp data-start=\"2973\" data-end=\"3149\"\u003eIf this size does not match your requirements, please contact us directly. As the manufacturer, we can supply a full range of sizes and specifications to suit your application.\u003c\/p\u003e\n\u003cp data-start=\"2973\" data-end=\"3149\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"2973\" data-end=\"3149\"\u003e \u003c\/p\u003e\n\u003ch3 data-end=\"178\" data-start=\"127\" data-section-id=\"1fq7bcg\"\u003e🔹 Filter Replacement (Quick \u0026amp; Clean Process)\u003c\/h3\u003e\n\u003cp data-end=\"290\" data-start=\"180\"\u003eChanging your KLEENOIL cartridge is a simple and clean process, designed for minimal mess and quick servicing.\u003c\/p\u003e\n\u003col data-end=\"1488\" data-start=\"292\"\u003e\n\u003cli data-end=\"377\" data-start=\"292\" data-section-id=\"1twla4\"\u003e\n\u003cstrong data-end=\"313\" data-start=\"295\"\u003eRemove the lid\u003c\/strong\u003e\u003cbr data-end=\"316\" data-start=\"313\"\u003eUndo the retaining bolts and keep them safe for refitting.\u003c\/li\u003e\n\u003cli data-end=\"520\" data-start=\"379\" data-section-id=\"13akw6u\"\u003e\n\u003cstrong data-end=\"411\" data-start=\"382\"\u003ePrepare the new cartridge\u003c\/strong\u003e\u003cbr data-end=\"414\" data-start=\"411\"\u003eUnpack the new filter and keep the protective bag aside—you’ll use this for removal of the old element.\u003c\/li\u003e\n\u003cli data-end=\"769\" data-start=\"522\" data-section-id=\"mmjt78\"\u003e\n\u003cstrong data-end=\"561\" data-start=\"525\"\u003eRemove the used filter (cleanly)\u003c\/strong\u003e\u003cbr data-end=\"564\" data-start=\"561\"\u003ePlace the bag over the filter housing, reach in, and lift the used cartridge out using the web handles.\u003cbr data-end=\"673\" data-start=\"670\"\u003eCarefully turn the bag over the filter and seal it to contain oil residue for clean handling.\u003c\/li\u003e\n\u003cli data-end=\"959\" data-start=\"771\" data-section-id=\"dd4bwm\"\u003e\n\u003cstrong data-end=\"801\" data-start=\"774\"\u003eCheck and clean the lid\u003c\/strong\u003e\u003cbr data-end=\"804\" data-start=\"801\"\u003eWipe the lid with a clean cloth and remove the old lid seal.\u003cbr data-end=\"870\" data-start=\"867\"\u003eReplace with the new seal, ensuring the sealing surface is clean and free from debris.\u003c\/li\u003e\n\u003cli data-end=\"1092\" data-start=\"961\" data-section-id=\"wskncv\"\u003e\n\u003cstrong data-end=\"990\" data-start=\"964\"\u003eInstall the new filter\u003c\/strong\u003e\u003cbr data-end=\"993\" data-start=\"990\"\u003eInsert the new cartridge with the \u003cstrong data-end=\"1059\" data-start=\"1030\"\u003ebrass ring facing upwards\u003c\/strong\u003e, pushing it fully into position.\u003c\/li\u003e\n\u003cli data-end=\"1192\" data-start=\"1094\" data-section-id=\"1uy3ysl\"\u003e\n\u003cstrong data-end=\"1117\" data-start=\"1097\"\u003eRefit and secure\u003c\/strong\u003e\u003cbr data-end=\"1120\" data-start=\"1117\"\u003eReplace the lid and tighten the bolts evenly to ensure a secure seal.\u003c\/li\u003e\n\u003cli data-end=\"1360\" data-start=\"1194\" data-section-id=\"15zlofx\"\u003e\n\u003cstrong data-end=\"1214\" data-start=\"1197\"\u003eRun and check\u003c\/strong\u003e\u003cbr data-end=\"1217\" data-start=\"1214\"\u003eStart the system and allow it to run for a few minutes.\u003cbr data-end=\"1278\" data-start=\"1275\"\u003eCheck the lid area to confirm there are \u003cstrong data-end=\"1333\" data-start=\"1321\"\u003eno leaks\u003c\/strong\u003e and the seal is effective.\u003c\/li\u003e\n\u003cli data-end=\"1488\" data-start=\"1362\" data-section-id=\"2gvjsu\"\u003e\n\u003cstrong data-end=\"1388\" data-start=\"1365\"\u003eDispose responsibly\u003c\/strong\u003e\u003cbr data-end=\"1391\" data-start=\"1388\"\u003eDispose of the used cartridge in accordance with local regulations for oil-contaminated waste.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Kleenoil","offers":[{"title":"Default Title","offer_id":52903882490203,"sku":null,"price":72.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1002\/7499\/5547\/files\/SDFC1888KF85_Filter_Cartridge_-_Render.jpg?v=1776094425","url":"https:\/\/kleenoil.myshopify.com\/products\/kleenoil-original-sdfc2088kf85-polypropylene-for-water-based-fluids-only","provider":"Kleenoil  Hydraulics","version":"1.0","type":"link"}